 World- leading mirror type goniophotometer

 Patents issued in China, Germany and USA,“China Excellent Patent Award”

 Fully meets IESNA LM-79 and GB/T 24824

 National 863 program (national high tech research & development program)  achievement

 Widely applied in NVLAP accredited labs


Back


1. Basic working principle

GO-R5000 is based on CIE C-γ system and measures intensity distribution on C-planes or cone surfaces. It can also achieve CIE A-α,CIE B-β solutions by software. GO-R5000 can be widely used in the measurement of all types of lighting sources like  lamps, luminaires, indoor lights, outdoor lights, street lights, flood lights with very high accuracy.

Export format: *.GOS *.CIE *.CEN *.IES *.TM14 *.CIB *.LDT, which can directly match International Universal Lighting Design Software, such as Dialux, AGI32, Lumen-Micro.

The spatial spectral/colorimetric quantities and spectral/color uniformity (optional) and luminance distribution and luminance uniformity (optional) can be achieved by the goniophotometer system.



2. Main specifications

Photometry

Accuracy of photometer head

CLASS L, f1′<1.5%

Linearity of photometry

0.2%

Reproducibility of photometry

0.1% for stable lamps

The detecting ability of photometer

1×10-5/1×10-4/1×10-3 lx/0.01lxon request

Measuring range of illuminance

1×10-5/1×10-4/0.001lx~20klx/200klxon request

Measuring range of the luminous intensity

4.0×10-5/4.0×10-4/4.0×10-3 cd/

4.0×10-2 cd~1.8×107 cd/1.8×10cd

Angle

C axis

Rotation Range

0°~ 360°

Angle accuracy

0.1°/0.05°The highest accuracy in the world

Γ axis

Rotation Range

-180°~ +180°

Angle accuracy

0.1°/0.05°The highest accuracy in the world

Measurement Speed

Up to 3rp, and adjustable

Color distribution

Optical bench

detector: HAMAMATSU customized TE-cooled  Back-thinned Array CCD, CCD cooled temperature:-10℃Stability±0.05℃CCD pixels1024×128allow Binning model

F2.0 holographic grating with flat-field correction

Integrating time

9ms-60s

Spectrograph

Wavelength range380nm-780nm

wavelength accuracy±0.2nmBand pass3nm

Stray light5.00E-05((BWCT))

Colorimetry parameters

Accuracy of chromaticity (x,y)±0.0003under Illuminant A

Chromaticity(x,y) reproducibility ±0.00015x±0.0002y(blue LED

Luminance  distribution

Luminance function

Luminance distribution, luminance uniformity  and UGR

Luminance Measurement range

0.01cd/m215.00kcd/m2

Luminance accuracy

±5%

3. Order information

Model

GO-R5000-XXX-STD

GO-R5000-XXX-LRG

GO-R5000-XXX-SML

GO-R5000-XXX-CST

Max.characteristics of lamps or luminaires

Size

1600mm

2000mm

800mm

on request

weight

50kg

80kg

30kg

on request

power

3000W/10A

AC/DC

3000W/10A

AC/DC

3000W/10A

AC/DC

on request




Back

 